28 resultados para TRANSCRANIAL ULTRASOUND

em University of Queensland eSpace - Australia


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: Transcranial Doppler (TCD) ultrasonography is a technique that uses a hand-held Doppler transducer (placed on the surface of the cranial skin) to measure the velocity and pulsatility of blood flow within the intracranial and the extracranial arteries. This review critically evaluates the evidence for the use of TCD in the critical care population. Discussion: TCD has been frequently employed for the clinical evaluation of cerebral vasospasm following subarachnoid haemorrhage (SAH). To a lesser degree, TCD has also been used to evaluate cerebral autoregulatory capacity, monitor cerebral circulation during cardiopulmonary bypass and carotid endarterectomies and to diagnose brain death. Technological advances such as M mode, colour Doppler and three-dimensional power Doppler ultrasonography have extended the scope of TCD to include other non-critical care applications including assessment of cerebral emboli, functional TCD and the management of sickle cell disease. Conclusions: Despite publications suggesting concordance between TCD velocity measurements and cerebral blood flow there are few randomized controlled studies demonstrating an improved outcome with the use of TCD monitoring in neurocritical care. Newer developments in this technology include venous Doppler, functional Doppler and use of ultrasound contrast agents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Motion-induced blindness (MIB) is a phenomenon, perhaps related to perceptual rivalry, where stationary targets disappear and reappear in a cyclic mode when viewed against a background (mask) of coherent, apparent 3-D motion. Since MIB has recently been shown to share similar temporal properties with binocular rivalry, we probed the appearance-disappearance cycle of MIB using unilateral, single-pulse transcranial magnetic stimulation (TMS)-a manipulation that has previously been shown to influence binocular rivalry. Effects were seen for both hemispheres when the timing of TMS was determined prospectively on the basis of a given subject's appearance-disappearance cycle, so that it occurred on average around 300 ms before the time of perceptual switch. Magnetic stimulation of either hemisphere shortened the time to switch from appearance to disappearance and vice versa. However, TMS of left posterior parietal cortex more selectively shortened the disappearance time of the targets if delivered in phase with the disappearance cycle, but lengthened it if TMS was delivered in the appearance phase after the perceptual switch. Opposite effects were seen in the right hemisphere, although less marked than the left-hemisphere effects. As well as sharing temporal characteristics with binocular rivalry, MIB therefore seems to share a similar underlying mechanism of interhemispheric modulation. Interhemispheric switching may thus provide a common temporal framework for uniting the diverse, multilevel phenomena of perceptual rivalry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of high power ultrasound waves on physical, biochemical, and microbial properties of meat have been the subject of a great deal of interest in recent years. The present review details the basic principles underlying the effects of ultrasound on the properties of food systems, followed by discussion of specific effects of high power ultrasound on meat products, including muscle, cellular, and subcellular components. In addition, the specific effects of high power ultrasound on the following parameters are discussed: enzyme activities and efficiencies, muscle proteolysis, quality criteria such as tenderness; extraction of protein, gelation, and restructuring of meat products and germicidal properties against meat micro-organisms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hepatosplenic measurements among 550 Chinese subjects, aged 3-59 years from Yueyang city-a nonendemic area for schistosomiasis in Hunan province, China-were performed to define normal ranges of ultrasound organometry for assessing hepatosplenic, morbidity in Schistosoma japonicum infection. Measurements included the size of the liver (left lobe and right lobe), the main portal vein stem, the peripheral periportal vein branches, and spleen length and thickness. The results document the significant relationship between body height and organometric parameters. The reference values stratified by body height improve the accuracy of assessment. Thus, height-based normal ranges established in this study can be applied in hospital routine and in field studies of patients infected with S. japonicum in Hunan province and in other endemic areas of China. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Extraction and reconstruction of rectal wall structures from an ultrasound image is helpful for surgeons in rectal clinical diagnosis and 3-D reconstruction of rectal structures from ultrasound images. The primary task is to extract the boundary of the muscular layers on the rectal wall. However, due to the low SNR from ultrasound imaging and the thin muscular layer structure of the rectum, this boundary detection task remains a challenge. An active contour model is an effective high-level model, which has been used successfully to aid the tasks of object representation and recognition in many image-processing applications. We present a novel multigradient field active contour algorithm with an extended ability for multiple-object detection, which overcomes some limitations of ordinary active contour models—"snakes." The core part in the algorithm is the proposal of multigradient vector fields, which are used to replace image forces in kinetic function for alternative constraints on the deformation of active contour, thereby partially solving the initialization limitation of active contour for rectal wall boundary detection. An adaptive expanding force is also added to the model to help the active contour go through the homogenous region in the image. The efficacy of the model is explained and tested on the boundary detection of a ring-shaped image, a synthetic image, and an ultrasound image. The experimental results show that the proposed multigradient field-active contour is feasible for multilayer boundary detection of rectal wall

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Study Design: Randomized controlled trial. Objective: To determine if the provision of visual biofeedback using real-time ultrasound imaging enhances the ability to activate the multifidus muscle. Background: Increasingly clinicians are using real-time ultrasound as a form of biofeedback when re-educating muscle activation. The effectiveness of this form of biofeedback for the multifidus muscle has not been reported. Methods and Measures: Healthy subjects were randomly divided into groups that received different forms of biofeedback. All subjects received clinical instruction on how to activate the multifidus muscle isometrically prior to testing and verbal feedback regarding the amount of multifidus contraction, which occurred during 10 repetitions (acquisition phase). In addition, 1 group received visual biofeedback (watched the multifidus muscle contract) using real-time ultrasound imaging. All subjects were reassessed a week later (retention phase). Results: Subjects from both groups improved their voluntary contraction of the multifidus muscle in the acquisition phase (P

Relevância:

20.00% 20.00%

Publicador: